Result for code 2

The overall score of this system is given in the lower right cell of the table below. This is the average sensitivity at an average number of false positives per scan of 1/8, 1/4, 1/2, 1, 2, 4 and 8. The sensitivities at these false positive rates for all nodules and all subsets of nodules are tabulated below.

The following table summarizes the results.

FPs/scan1/8 1/4 1/21 24 8average
small nodules0.1110.1710.2220.2990.4530.5380.5810.339
large nodules0.1110.1220.1440.2220.2780.3440.3670.227
isolated nodules0.2140.2620.3100.4760.5950.6670.6670.456
vascular nodules0.1050.1160.1630.1980.2670.3370.3600.221
pleural nodules0.0170.0170.0170.0850.2200.3390.3900.155
peri-fissural nodules0.1710.3140.3710.4570.6000.6860.7430.478
all nodules0.1110.1500.1880.2660.3770.4540.4880.291